0
0
*The image is illustrative and the product may differ from the one shown in the image

Multimetrs ar TRUE RMS, YT-730933, YATO, 10mA-1000A, AC/DC, 0-750V, 0-1000V, 0-60MΩ, 0-100mF, 0-10MHz, -30°C līdz +1000°C

Code:
YT-730933
37,70
Availability: available in 8 w.d.
Ar kurjeru visā Latvijā
Ar kurjeru visā Latvijā
You will be contacted about delivery time. From 4,99 EUR

Piegādes punktos
Piegādes punktos
You will be contacted about delivery time. From 3,39 EUR
INSERV – Remtes street 21, Riga
Monday
8:00 - 17:00

Tuesday
8:00 - 17:00

Wednesday
8:00 - 17:00

Thursday
8:00 - 17:00

Friday
8:00 - 17:00

Saturday

Sunday
INSERV – Ulmana parks 2, Marupe
Monday
8:00 - 17:00

Tuesday
8:00 - 17:00

Wednesday
8:00 - 17:00

Thursday
8:00 - 17:00

Friday
8:00 - 17:00

Saturday

Sunday
YATO Read more
Reviews about us:
google.ee hind.ee hinnavaatlus.ee
See a mistake? Let us know
Ātra piegāde
Ātra piegāde
Drošs pirkums
Drošs pirkums
Augsts klientu vērtējums
Augsts klientu vērtējums

Technical specification:

Feed From batteries
Weight, kg 0.2
Voltage, V 0 — 1000
Battery type 3x1.5V; AAA
Material Plastic
Application temperature, ° C -30 — 1000; 0 — 40
Size, mm 194x75x35
Uzglabāšanas temperatūra, C° 10 — 50
Display type LCD
Charging level indicator yes
Front lighting yes
LED backlight yes
Data Hold yes
Continuity test, Ω 0 — 50
Alternating voltage 0 — 750
Resistance, MΩ 0 — 60
Alternating current, A 0-1000 A
Auto measurement range yes
Capability, mF 0 — 100
Conduction test yes

Description:

The YATO YT-730933 is a universal clamp meter featuring TRUE RMS functionality, capable of automatic and manual ranging. It allows both basic and advanced electrical quantity measurements to be taken seamlessly. With its clamp design, it can measure both DC and AC current ranging from 10 mA to 1000 A, all without the need to disconnect the circuit or the power source. This meter enables the measurement of higher currents compared to conventional electric meters. The probe cables are insulated with silicone, making them flexible and resistant to high temperatures.


Basic Measurements:


  • AC voltage measurement: A.C. 0-750 V, TRUE RMS (40-1000 Hz)
  • DC voltage measurement: D.C. 0-1000 V
  • AC current measurement: A.C. 0-1000 A, TRUE RMS (40-1000 Hz)
  • DC current measurement: D.C. 0-1000 A
  • Resistance measurement: 0–60 MΩ
  • Diode test: IF 2 mA, UR 3.2 V
  • Continuity test: 0-50 Ω

Additional Measurements:


  • Capacitance measurement: 0-100 mF
  • Frequency measurement: 0-10 MHz
  • Temperature measurement: -30°C to 1000°C
  • Non-contact AC voltage detection: NCV
  • Measurement of inrush current
  • Phase presence measurement (sampler function)

Measurement Accuracy:


For example, the accuracy determination for AC current measurements at a calculated result of 30 A is:

  • The measurement accuracy of the YATO YT-730933 meter for this range is: ±(2.5% + 10), with a resolution of 0.01 A
  • Formula for calculating measurement error: (measurement result x 2%) + 30 x resolution
  • Calculations: (30 x 2.5%) + 10 x 0.01 = 0.75 + 0.1 = 0.85 A

The actual measurement result including error for a 30 A indication = 30 ± 0.85 A.


  • The result including measurement error for the AC voltage measurement indication: 235 V = 235 ± 2.85 V
  • The result including measurement error for the DC voltage measurement indication: 12 V = 12 ± 0.146 V

A table with resolution and accuracy for each measurement can be found in the user manual.


Built-in Functions:


  • TRUE RMS - This function displays the true RMS value of AC voltage or current. Unlike averaging meters, devices with TRUE RMS can show the correct value for not only sinusoidal waveforms but also for non-linear waveforms distorted by harmonics or shapes such as square or triangular waves. It is essential in circuits involving switch-mode power supplies, motor drives, HVAC installations, etc.
  • NCV - Non-contact AC voltage detection using an inductive method. The meter detects voltage presence in insulated wires and can indicate the phase wire.
  • LINE - Contact AC voltage detection, functioning as a traditional voltage sampler. When the probe is inserted into a socket, if a phase is present, four dashes will appear on the display, the signal LED will light up and an intermittent beep will sound.
  • AUTO - Automatic measurement range adjustment. With this function, the multimeter can automatically determine the best range for measurement. The meter begins in AUTO mode by default.
  • RAN - Manual range adjustment.
  • DATA HOLD - Keeps the currently measured value displayed.
  • INR - Measures inrush current using measuring clamps, detecting current 80 ms after device startup.

Additional Information:


  • LCD display, with a maximum displayed result of 6000.
  • Illumination for the display and clamp area.
  • Audible signal in continuity tests for resistances below 50 Ω.
  • Clamp spans up to 25 mm.
  • Measurement probes are 14 cm long.
  • Cable length including probes: 103 cm.
  • Cable diameter including insulation: 3.6 mm.
  • Cover included.
  • Designed with overload protection.
  • Automatic shutdown after 15 minutes of inactivity.
  • Capability to disable automatic shutdown.
  • Low battery indicator.
  • Power supply: three 1.5 V (AAA) batteries.

Warning!


Current measurements with clamp meters are performed only on a single conductor. Clamping around a multi-conductor cable without isolating one wire will result in incorrect readings or zero current flow.